All
electrical systems & equipment require a power source (or sources) and
distribute these sources to power downstream equipment, this is called power
distribution. Electrical power distribution needs to be distributed in a safe
and efficient manner. Electrical switchgear is an essential element of this
distribution. Modern metal-clad switchgear has changed with new tech. But, many
traits remain the same. The following is a summary of industry common
applications and an attempt to explain what is included in the solutions.
Switchgear is essentially a large metal box that houses items like circuit
breakers or fuses to protect the equipment it is distributing power to. Much
like the circuit breaker box on the side of your house that send power safely
into you home, the circuit break if it senses an issue it will trip before
allowing electricity to continue to pass o that individual circuit. As a
comparison the circuit breaker panel on the side of your house could be compared
to a small car that can carry a few people, switchgear would be compared to a
heavy duty large copper bus system that can carry dozens of people. Now lets
dive a little deeper into Switchgear. Electrical
Switchgear Manufacturers
Components
of Switchgear
As
stated in the opening paragraph, Switchgear distributes power to smaller loads.
The main power source could com various different sources. It has enough
capacity to power the total need. A user of that power, often, is tasked with
safely distributing this power once the service entrance from a utility is
established. The most common way to make such a point is a metal enclosure,
made in a factory. It includes at least the following:
Metal
enclosure called a switchgear enclosure
Typical
paint colors such as industry standard ANSI Gray paint. This also serves as a
corrosion protectant.
Bus
Bars to carry the power source
Non-metallic
barriers and insulators to keep the bus bar away from the metal enclosure
Main
breaker, Main Fused Disconnect, or Main non-fused disconnect
Protection
devices such as breakers or fuses
Protection
Relays these are common on low voltage switchgear but medium and high Voltage
switchgear they are an requirement for each breaker.
Hardware
there are specific types of fasteners and bolts used in switchgear systems that
are teste and approved by the manufacture. Its important to note you cannot
just use any standard hardware when making replacements
Control
devices such as pilot lights for indication, switches or push buttons to
control the protection devices to do various operations such as Open / or
Close/
Switchgear
often includes components. They allow unsupervised and automated protection
from failures in the electrical distribution system.
Instrument
transformers are electrical devices that sense power. They reduce voltage and
current to safe levels. These levels are normally 120VAC and 5A. Relays and
meters interpret these signals to show the state of the power.
Circuit
protectors are extra power sensors. They may or may not work with the
instrument transformers. Their job is to stop the electrical system from damage
to its insulation. This damage can be from short-circuits (phase to phase) or
phase to ground. Examples are circuit breakers, current interrupting fuses, and
load-break switches (manual and electrically operated).
Protective
relays interpret the power system operation. They often use the outputs of the
instrument transformers. Based on those inputs, they send signals to alarm
personnel or operate the circuit isolators. This isolates faults or overloads
safely.
Metering
– allows for monitoring the power system operation. Control power
transformer(s) allow for efficient power delivery. They provide power to the
devices for operating the switchgear.
Power
transformers – unit substations, typically dry-type fan cooled. Using
switchgear to hold many of these components has three benefits. It is efficient
to make and install. It protects against outside factors that can harm
electrical systems. And it guards people and property from the dangers of high
voltage.
What
do the terms and mean when referring to switchgear?
When
you see a push button labeled “open” or “close” on the outside of switchgear or
on the front of a breaker, it controls the contacts inside the breaker.
Pressing
“open” disconnects the contacts, turning off or restricting the power flow
through the breaker. Pressing “close” reconnects the contacts, allowing power
to flow through the breaker to its downstream source. Think of this power flow
like water running through a hose connected to a valve with push buttons:
pressing “open” turns the valve, allowing water to flow, while pressing “close”
shuts the valve, stopping the water flow. Custom
Switchgear Manufacturers
As
mentioned earlier, fuses can serve as protection devices, but they cannot be
opened or closed like a breaker. If a fuse blows, it means the circuit is
interrupted, and power will no longer flow through it. Fuses contain a strip of
thin metal that melts or blows out when it reaches a certain temperature,
stopping the power flow. To control a fuse in a piece of switchgear, a separate
disconnect is needed in front of it. For low voltage, this would be a non-fused
switch or knife switch to perform the open and close functions. For medium
voltage, a load break switch or a larger equivalent is required, similar in
function but scaled up.